We use cookies to enhance user experience as well as analyze performance and traffic on our website. This information can lead to a more personalized web experience. By continuing to use and browse our site, you agree to our Privacy policy

Viega LLC – Recognized leader in press technology for plumbing and piping systems

Select Country

  • AAlbania
  • Algeria
  • Australia
  • Austria
  • Azerbaijan
  • BBahrain
  • Belgium
  • Belize
  • Bosnia
  • Brazil
  • Bulgaria
  • CCanada
  • Caribbean Islands
  • Chile
  • China
  • Colombia
  • Costa Rica
  • Croatia
  • Cyprus
  • Czech Republic
  • DDenmark
  • Dominican Republic
  • EEcuador
  • Egypt
  • Estonia
  • FFinland
  • France
  • GGeorgia
  • Germany
  • Greece
  • Guatemala
  • HHonduras
  • Hong Kong
  • Hungary
  • IIceland
  • India
  • Indonesia
  • Iraq
  • Ireland
  • Israel
  • Italy
  • JJapan
  • Jordan
  • KKazakhstan
  • Kosovo
  • Kuwait
  • LLatvia
  • Lebanon
  • Lithuania
  • Luxembourg
  • MMacedonia
  • Malaysia
  • Malta
  • Mexico
  • Moldavia
  • Montenegro
  • Morocco
  • NNamibia
  • Netherlands
  • New Zealand
  • Nicaragua
  • Norway
  • OOman
  • PPakistan
  • Panama
  • Peru
  • Philippines
  • Poland
  • Portugal
  • QQatar
  • RRepublic of Korea
  • Romania
  • SSaudi Arabia
  • Serbia
  • Singapore
  • Slovakia
  • Slovenia
  • South Africa
  • Spain
  • Sweden
  • Switzerland
  • TTaiwan
  • Thailand
  • Trinidad and Tobago
  • Tunisia
  • UUkraine
  • United Arab Emirates
  • United Kingdom
  • United States of America
  • VVietnam
  • YYemen

Viega MegaPress Stainless

For use with 304 and 316 IPS stainless steel

Benefits
  • Secure connections in less than 16 seconds
  • Approved for use with Schedule 5 to Schedule 40 pipe
  • MegaPress Stainless 316 comes with a choice of EPDM or FKM sealing elements

Water/Liquids                                                

Hot and Cold Potable Water  Test pressure 600 psi
Rainwater / Graywater
Chilled Water    
≤50% Ethylene / Propylene glycol 
Hydronic Heating Water     ≤50% Ethylene / Propylene glycol
Treated Water Fully desalinated, deionized, demineralized, distilled (open system)
Reverse Osmosis Water 
<1 MΩ
Paraffin Wax
Methyl Ethyl Ketone
Isopropyl Alcohol 
Nitric Acid 
Concentration ≤10%
Phosphoric Acid 
Concentration ≤25%
Fire Sprinkler     
NFPA 13, 13D, 13R 
Steam     Low-pressure 
Steam     Residential 


Fuels/Oils/Lubricants

Ethanol  Pure grain alcohol
Mineral Oil 
Lube Oil     
Petroleum based  
Diesel Exhaust Fluid (DEF) 
Biodiesel     ASTM D6751  
Heating Fuel Oil 
Diesel Fuel
Kerosene             
Gear Oil   
Lubricant
Automatic Transmission Fluid
Hydraulic Oil
Engine Oil
Engine Coolant
Waste Oil


Gases

Compressed Air     Oil Concentration ≤25 mg/m  
Compressed Air     Oil Concentration >25 mg/m 
Nitrogen - N2
Carbon Dioxide - CO2     
Dry
Argon - Ar
Ammonia  
Anhydrous
Ammonia  
Ammonia environment7
Oxygen - O2     
Non-medical Keep free of oil and grease
Hydrogen - H2
Acetylene     
Test pressure 350 psi
Vacuum     Minimum absolute pressure Maximum differential pressure


Special Media

Methanol
Latex Paint
Urea Solution 
 Concentration ≤40%
Caustic Soda  Concentration ≤50%
Acetone  Liquid


For additional information, please see the approved applications chart. View Viega Approved Applications

  • ASME B31: Code for Pressure Piping
  • ASME B31.1: Power Piping
  • ASME B31.3: Process Piping
  • ASME B31.9: Building Services Piping
  • ASTM A312: Standard Specification for Seamless, Welded and Heavily Cold Worked Austenitic Stainless Steel Pipes
  • IACS UR P2: Rules for piping design, construction and testing
  • IAPMO: PS-117: Press Connections
  • IAPMO: Uniform Mechanical Code (UMC)
  • IAPMO: Uniform Solar, Hydronics and Geothermal Code (USHGC)
  • ICC: International Mechanical Code (IMC)
  • ICC: International Residential Code (IRC)
  • ICC-​ES LC1002: Press-​connection Fittings for Potable Water Tube and Radiant Heating Systems
  • National Building Code of Canada (NBCC)
  • NFPA 13: Standard for the Installation of Sprinkler Systems
  • NFPA 13D: Standard for the Installation of Sprinkler Systems in One- and Two-​Family Dwellings and Manufactured Homes
  • NFPA 13R: Standard for the Installation of Sprinkler Systems in Low-​Rise Residential Occupancies
  • ABS: American Bureau of Shipping Type Approval
  • BV: Bureau Veritas Type Approval
  • Canadian Registration Number (CRN): 14541.5 A/B/C
  • DNV GL: Det Norske Veritas Germanischer Lloyd Type Approval
  • FM Class 1920: Pipe Couplings and Fittings for Aboveground
    Fire Protection Systems (½" to 2" only)
  • IAPMO file 10555 (MegaPress 304 FKM)
  • ICC-​ES PMG-1451 (MegaPress 304)
  • LR: Lloyd’s Register Type Approval
  • RINA: Registro Italiano Navale
  • ANSI/CAN/UL 213: Standard for Rubber Gasketed Fittings for Fire-​Protection Service (½" to 3" only)
  • United States Coast Guard Acceptance Letter 2019‑3660

NOTE
A white dot on a Viega MegaPress 304 fitting indicates Smart Connect technology with an FKM sealing element.